Lingkungan Fisik dan Angka Kuman Udara Ruangan di Rumah Sakit Umum Haji Makassar, Sulawesi Selatan

M. Tahir Abdullah, Buraerah Abdul Hakim

Abstract


Udara merupakan salah satu media lingkungan tempat bakteri, virus, dan fungi hidup dan berkembang. Oleh karena mikroorganisme tersebut memerlukan berbagai persyaratan untuk tumbuh dan berkembang, faktor-faktor lingkungan fisik udara tertentu dapat berhubungan dengan angka kuman. Untuk menentukan hubungan ini, telah dilakukan studi potong lintang di ruang rawat inap pasien Rumah Sakit Umum Haji Makasar. Kualitas faktor-faktor lingkungan fisik (pencahayaan, suhu, kelembaban relatif, dankepadatan ruangan) dan angka kepadatan kuman dalam 5 ruang rawat inap (pavilion, kelas 1, kelas 2, kelas 3, dan recovery room) diukur 3 kali (pagi, siang, dan sebelum matahari terbenam) pada 3 titik pengukuran berbeda setiap ruang. Hasilnya menunjukkan bahwa lebih dari 91% angka kuman dan 71%-87% kualitas lingkungan fisik tidak memenuhi kesehatan yang dipersyaratkan oleh Keputusan Menteri Kesehatan RI No. 1204/MENKES/SK/X/2004. Berdasarkan 4 faktor lingkungan fisik yang diukur, hanya kelembaban relatif yang secara langsung berhubungan dengan angka kepadatan kuman (nilai p = 0,023), meskipun korelasi liniernya sangat rendah (korelasi Pearson 0,299). Sesuai dengan tingkat korelasi ini, kontribusi semua faktor lingkungan fisik kepada angka kuman hanya 14,6% (R2 = 0,382). Apabila disesuaikan dengan populasi standar, kontribusi ini hanya 6%.Kata kunci: Angka kuman, faktor lingkungan fisik, rumah sakit umum hajiAbstractAir is an environmental medium where microbe such as bacteria, viruses, and fungi can live and may infect exposed people. As the microbes require appropriate condition to live and grow, particular physical environment of air may associate with microbial density rate. To determine this association, across-sectional study has been conducted in in-patient wards of Makassar Public Hospital of Hajj. Quality of physical environment factors (lighting, temperature, relative humidity, and room density) and microbial density rate of indoor air in five in-patient wards (pavilion, class 1, class 2, class 3, and recovery room) were measured three times (morning, afternoon, and before sunset) at three different sampling sites of each room. The results show that more than 91% microbe rate and 71%-87% quality of physical environmental factors do not comply with the health requirements as regulated in the Ministry of Health Decision of 1204/MENKES/ SK/X/2004. Of four physical environmental factors quantified, only relative humidity is associated directly with the microbe rate (p = 0,023), although its linear correlation is very low (Pearson correlation 0,299). Correspondingly, contribution of all physical environmental factors to the microbe rate is only 6% (R2 = 0,382). Adjusted to the population standard, this contribution is only 6%.Key words: Physical environment factor, microbe rate, hajj public hospital

Full Text:

PDF


DOI: http://dx.doi.org/10.21109/kesmas.v5i5.128

Refbacks

  • There are currently no refbacks.